Neurosoft Company
Neurosoft Company
Русский» Français» Portugal» Português(BR)» Türkçe» Български»

Neuro-MEP-Micro

2-channel portable digital EMG and EP system with a built-in miniature dedicated keyboard


neuro-mep-micro (high resolution).zip
(pdf-file, 19.57 MB)

neuro-mep-micro.zip
(pdf-file, 432 KB)


USB connection
ISO quality certificate
CE conformance certificate
Certificates of conformance to CIS requirements
Software on .NET platform

FeaturesDelivery SetBack to EMG Systems


  • Electroneuromyography: motor and sensory nerve conduction study (NCS), F-wave, H-reflex (also including paired stimulation), motor and sensory inching
  • Electromyography: spontaneous activity, interference curve, motor unit potentials (MUP)
  • Neuromuscular junction: repetitive stimulation, jitter (single fiber EMG)
  • Motor unit number estimation (MUNE)
  • Additional EMG techniques: blink reflex, sacral reflex, bulbocavernous reflex, T-reflex*, galvanic skin responses
  • Somatosensory evoked potentials (SEP)
  • Transcranial magnetic stimulation (TCMS)**
  • Heart rate variability (HRV)***

Digital EMG and EP system Neuro-MEP-Micro can be supplemented with the Neuro-EP software module and set of stimulators for short-, middle- and long-latency auditory, visual and cognitive (Р300, MMN, CNV) EP study.

F-wave
 

Neuro-MEP-Micro Features

Electroneuromyography:

  • registration and analysis of M-wave characteristics and sensory action potential
  • evaluation of motor/sensory conduction velocity
  • F-wave, H-reflex (also including paired stimulation) parameters study
  • magnetic stimulation of spinal roots and peripheral nerves with the further classic analysis of motor response**
  • blink reflex, sacral reflex, bulbocavernous reflex, T-reflex*, galvanic skin responses
  • motor and sensory inching

Neuromuscular Junction Study:

  • analysis of M-wave decrement during repetitive stimulation of motor nerve
  • tetanization and posttetanic phenomena study
  • user-defined stimulation algorithm creation

Motor Unit Potentials (MUP):

  • registration and analysis of spontaneous activity phenomena
  • detection of MUP in automatic and manual modes
  • automatic analysis of MUP parameters, determination of denervation-reinnervation process stage

Motor Unit Number Estimation (MUNE):

  • registration and semiautomatic analysis with evaluation of motor unit quantity by incremental technique

Spontaneous and Interference Electromyography:

  • spontaneous activity
  • turn-amplitude analysis of interference EMG
  • amplitude-frequency analysis of interference EMG
  • spectrum analysis of interference EMG
  • rectified EMG
  • EMG sound playback

Transcranial Magnetic Stimulation (TCMS)**:

  • determination of central motor conduction time of patients suffering from nervous system demyelination diseases, in particular, multiple sclerosis
  • automatic calculation of root delay at F-wave and magnetic stimulation combined study

Somatosensory Evoked Potentials (SEP):

  • short- and long-latency SEP

Auditory Evoked Potentials (AEP)***:

  • registration of short-latency (brainstem), middle- and long-latency AEP
  • objective audiometry

Vestibular Evoked Myogenic Potentials (VEMP)***:

  • registration of VEMP in patients with Meniere's disease, superior canal dehiscence, vestibular neuritis, multiple sclerosis, migraine, spinocerebellar degeneration

Visual Evoked Potentials (VEP)***:

  • registration of flash visual evoked potentials
  • registration of reversal pattern visual evoked potentials

Heart Rate Variability (HRV)***:

  • frequency-domain analysis of heart rate
  • cardiovascular reflex tests performing

NCS. Sensory conduction velocity
 

Motor unit potentials
 

Somatosensory evoked potentials (SEP)
 

Interference EMG
 

Transcranial magnetic stimulation
 

Repetitive stimulation
 

Heart rate variability
 

 

* if tendon hammer is available
** if Neuro-MS magnetic stimulator is available
*** if corresponding accessories and software are available

Neuro-MEP-Micro Delivery Set

Neuro-MEP-Micro Extra Delivery Set


Footswitch
3 pedals


Tendon hammer
tendon hammer for T-reflex


Temperature sensor


Neuro-MS
magnetic stimulator for cerebral cortex motor zones and peripheral nervous system


Neuro-EP for Neuro-MEP-Micro
software and equipment for short-, middle- and long-latency auditory, somatosensory, visual and cognitive (P300, MMN, CNV) EP study


Neuro-ERG 
software and equipment for electroretinography (ERG) and electro-oculography (EOG) study


 

Poly-Spectrum-Rhythm/MEP
software and equipment for heart rate variability (HRV) analysis


Adapter for high resolution pattern-stimulator connection


Dedicated keyboard
dedicated keyboard for quick access to main commands of “Neuro-MEP.NET” software menu items


Clamp for dedicated keyboard


Isolation transformer TM-630


Optional Sofware

  • Neuro-EP software (“Neuro-MEP.NET” software with EP module for short-, middle-, and long-latency EP study (VEP, PR-VEP, ABR, SSEP, P300, MMN, CNV))
  • Neuro-ERG software (“Neuro-MEP.NET” software with ERG module for VEP, PR-VEP, ERG and EOG acquisition, analysis and storage)

According to safety standards all the computer equipment used with digital EEG system should be connected via isolation transformer.


Back to EMG Systems

[ Top ]  HomeProductsSearch
Updated 27.04.2009
+7 4932 24 04 34 | | 2005—2012 © Neurosoft, Ivanovo, Russia